TROYANOSYVIRUS
Volver a CVEs

CVE-2022-41629

HIGH
7.5

Descripcion

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.

Detalles CVE

Puntuacion CVSS v3.17.5
SeveridadHIGH
Vector CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Vector de ataqueNETWORK
ComplejidadLOW
Privilegios requeridosNONE
Interaccion usuarioNONE
Publicado10/31/2022
Ultima modificacion11/21/2024
Fuentenvd
Avistamientos honeypot0

Productos afectados

deltaww:infrasuite_device_master

Debilidades (CWE)

CWE-306

Correlaciones IOC

Sin correlaciones registradas

This product uses data from the NVD API but is not endorsed or certified by the NVD.