← Volver a CVEs
CVE-2022-41629
HIGH7.5
Descripcion
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
Detalles CVE
Puntuacion CVSS v3.17.5
SeveridadHIGH
Vector CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Vector de ataqueNETWORK
ComplejidadLOW
Privilegios requeridosNONE
Interaccion usuarioNONE
Publicado10/31/2022
Ultima modificacion11/21/2024
Fuentenvd
Avistamientos honeypot0
Productos afectados
deltaww:infrasuite_device_master
Debilidades (CWE)
CWE-306
Referencias
https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07(ics-cert@hq.dhs.gov)
https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07(af854a3a-2127-422b-91ae-364da2661108)
Correlaciones IOC
Sin correlaciones registradas
This product uses data from the NVD API but is not endorsed or certified by the NVD.