TROYANOSYVIRUS
Volver a CVEs

CVE-2022-26649

CRITICAL
9.6

Descripcion

A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices.

Detalles CVE

Puntuacion CVSS v3.19.6
SeveridadCRITICAL
Vector CVSSCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vector de ataqueADJACENT_NETWORK
ComplejidadLOW
Privilegios requeridosNONE
Interaccion usuarioNONE
Publicado7/12/2022
Ultima modificacion11/21/2024
Fuentenvd
Avistamientos honeypot0

Productos afectados

siemens:scalance_x200-4p_irtsiemens:scalance_x200-4p_irt_firmwaresiemens:scalance_x201-3p_irtsiemens:scalance_x201-3p_irt_firmwaresiemens:scalance_x201-3p_irt_prosiemens:scalance_x201-3p_irt_pro_firmwaresiemens:scalance_x202-2irtsiemens:scalance_x202-2irt_firmwaresiemens:scalance_x202-2p_irtsiemens:scalance_x202-2p_irt_firmwaresiemens:scalance_x202-2p_irt_prosiemens:scalance_x202-2p_irt_pro_firmwaresiemens:scalance_x204-2siemens:scalance_x204-2_firmwaresiemens:scalance_x204-2fmsiemens:scalance_x204-2fm_firmwaresiemens:scalance_x204-2ldsiemens:scalance_x204-2ld_firmwaresiemens:scalance_x204-2ld_tssiemens:scalance_x204-2ld_ts_firmwaresiemens:scalance_x204-2tssiemens:scalance_x204-2ts_firmwaresiemens:scalance_x204irtsiemens:scalance_x204irt_firmwaresiemens:scalance_x204irt_prosiemens:scalance_x204irt_pro_firmwaresiemens:scalance_x206-1siemens:scalance_x206-1_firmwaresiemens:scalance_x206-1ldsiemens:scalance_x206-1ld_firmwaresiemens:scalance_x208siemens:scalance_x208_firmwaresiemens:scalance_x208_prosiemens:scalance_x208_pro_firmwaresiemens:scalance_x212-2siemens:scalance_x212-2_firmwaresiemens:scalance_x212-2ldsiemens:scalance_x212-2ld_firmwaresiemens:scalance_x216siemens:scalance_x216_firmwaresiemens:scalance_x224siemens:scalance_x224_firmwaresiemens:scalance_xf201-3p_irtsiemens:scalance_xf201-3p_irt_firmwaresiemens:scalance_xf202-2p_irtsiemens:scalance_xf202-2p_irt_firmwaresiemens:scalance_xf204siemens:scalance_xf204-2siemens:scalance_xf204-2_firmwaresiemens:scalance_xf204-2ba_irtsiemens:scalance_xf204-2ba_irt_firmwaresiemens:scalance_xf204_firmwaresiemens:scalance_xf204irtsiemens:scalance_xf204irt_firmwaresiemens:scalance_xf206-1siemens:scalance_xf206-1_firmwaresiemens:scalance_xf208siemens:scalance_xf208_firmware

Debilidades (CWE)

CWE-120CWE-120

Correlaciones IOC

Sin correlaciones registradas

This product uses data from the NVD API but is not endorsed or certified by the NVD.