CVE-2022-1368

CRITICAL
9.8

Descripcion

The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.

Detalles CVE

Puntuacion CVSS v3.19.8
SeveridadCRITICAL
Vector CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vector de ataqueNETWORK
ComplejidadLOW
Privilegios requeridosNONE
Interaccion usuarioNONE
Publicado9/6/2022
Ultima modificacion11/21/2024
Fuentenvd
Avistamientos honeypot0

Productos afectados

cognex:3d-a1000_dimensioning_systemcognex:3d-a1000_dimensioning_system_firmware

Debilidades (CWE)

CWE-306

Correlaciones IOC

Sin correlaciones registradas