TROYANOSYVIRUS
Volver a CVEs

CVE-2017-12235

HIGHCISA KEV
7.5

Descripcion

A vulnerability in the implementation of the PROFINET Discovery and Configuration Protocol (PN-DCP) for Cisco IOS 12.2 through 15.6 could allow an unauthenticated, remote attacker to cause an affected device to reload, resulting in a denial of service (DoS) condition. The vulnerability is due to the improper parsing of ingress PN-DCP Identify Request packets destined to an affected device. An attacker could exploit this vulnerability by sending a crafted PN-DCP Identify Request packet to an affected device and then continuing to send normal PN-DCP Identify Request packets to the device. A successful exploit could allow the attacker to cause the affected device to reload, resulting in a DoS condition. This vulnerability affects Cisco devices that are configured to process PROFINET messages. Beginning with Cisco IOS Software Release 12.2(52)SE, PROFINET is enabled by default on all the base switch module and expansion-unit Ethernet ports. Cisco Bug IDs: CSCuz47179.

Detalles CVE

Puntuacion CVSS v3.17.5
SeveridadHIGH
Vector CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Vector de ataqueNETWORK
ComplejidadLOW
Privilegios requeridosNONE
Interaccion usuarioNONE
Publicado9/29/2017
Ultima modificacion4/21/2026
Fuentekev
Avistamientos honeypot0

CISA KEV

VendedorCisco
ProductoIOS software
Nombre vulnerabilidadCisco IOS Software for Cisco Industrial Ethernet Switches PROFINET Denial-of-Service Vulnerability
Fecha inclusion KEV2022-03-03
Fecha limite remediacion2022-03-24
Uso en ransomwareUnknown

Productos afectados

cisco:industrial_ethernet_2000_16ptc-g-e_switchcisco:industrial_ethernet_2000_16ptc-g-l_switchcisco:industrial_ethernet_2000_16ptc-g-nx_switchcisco:industrial_ethernet_2000_16t67-b_switchcisco:industrial_ethernet_2000_16t67p-g-e_switchcisco:industrial_ethernet_2000_16tc-g-e_switchcisco:industrial_ethernet_2000_16tc-g-l_switchcisco:industrial_ethernet_2000_16tc-g-n_switchcisco:industrial_ethernet_2000_16tc-g-x_switchcisco:industrial_ethernet_2000_16tc-l_switchcisco:industrial_ethernet_2000_24t67-b_switchcisco:industrial_ethernet_2000_4s-ts-g-b_switchcisco:industrial_ethernet_2000_4s-ts-g-l_switchcisco:industrial_ethernet_2000_4t-b_switchcisco:industrial_ethernet_2000_4t-g-b_switchcisco:industrial_ethernet_2000_4t-g-l_switchcisco:industrial_ethernet_2000_4t-l_switchcisco:industrial_ethernet_2000_4ts-b_switchcisco:industrial_ethernet_2000_4ts-g-b_switchcisco:industrial_ethernet_2000_4ts-g-l_switchcisco:industrial_ethernet_2000_4ts-l_switchcisco:industrial_ethernet_2000_8t67-b_switchcisco:industrial_ethernet_2000_8t67p-g-e_switchcisco:industrial_ethernet_2000_8tc-b_switchcisco:industrial_ethernet_2000_8tc-g-b_switchcisco:industrial_ethernet_2000_8tc-g-e_switchcisco:industrial_ethernet_2000_8tc-g-l_switchcisco:industrial_ethernet_2000_8tc-g-n_switchcisco:industrial_ethernet_2000_8tc-l_switchcisco:industrial_ethernet_2000_series_firmwarecisco:ios

Debilidades (CWE)

CWE-20

Correlaciones IOC

Sin correlaciones registradas

This product uses data from the NVD API but is not endorsed or certified by the NVD.