TROYANOSYVIRUS
Volver a CVEs

CVE-2013-2807

N/A

Descripcion

Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size” that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599

Detalles CVE

Puntuacion CVSS v3.1N/A
Publicado3/26/2019
Ultima modificacion11/21/2024
Fuentenvd
Avistamientos honeypot0

Productos afectados

rockwellautomation:rslinx_enterprise

Debilidades (CWE)

CWE-190CWE-125

Correlaciones IOC

Sin correlaciones registradas

This product uses data from the NVD API but is not endorsed or certified by the NVD.